icecube.clsim.GetIceCubeDOMAcceptance module

icecube.clsim.GetIceCubeDOMAcceptance.GetIceCubeDOMAcceptance(domRadius=0.1651, efficiency=1.0, highQE=False)

this is taken from photonics/lib/efficiency.h:

Adopted into photonics Juli 1 2007 /Johan. Interpolation of data from Kotoyo Hoshina <kotoyo.hoshina@icecube.wisc.edu>: Jan 15 K.Hoshina : Found a wrong value at 260nm whicn I didn’t offer in July 1st 2007. Copied a value from 270nm.

0.0002027029 -> 0.0000064522

ROMEO wavelength effective area

This is the table of photo-electron acceptance of the IceCube PMT after through the glass+gel + PMT photocathode, as a function of wavelength. It corresponds to a 0p.e. threshold. The injection angle (off-axis angle) is 0deg.

The acceptances are calculated by:

acceptance = NPEs generated by photo-cathode (0P.E threshold) / Nphotons_inject_to_1m^2